Solar Protection IGU

The glass has the capability to reflect the sun energy and also absorb it and thus not let it into the room. These properties are typical mostly for the colored glass and the glass with special sunreflecting pyrolysed coating. Integrated into an insulating unit, this glass provides a reliable sun protection throughout the whole year.

Structure Light
prop.
Energy
prop.
U val. Noise
reduct.
[%] [%] [W/m2.K] Rw Noise
LT LR UVТ EA ЕR SF Air Argon dB suppr. [%]
4 colored* - 16 - 4 float 71 12 15 43 9 55 2.8 2.6 29 15
5 colored* - 16 - 4 float 66 11 14 54 7 46 2.7 2.5 30 20
4 blue /Azur/ - 16 - 4 float 71 12 15 43 9 55 2.8 2.6 29 15
5 blue /Azur/ - 16 - 4 float 51 8 21 55 7 46 2.7 2.5 30 20
4 stopsol clear - 16 - 4 float 58 38 30 14 31 60 2.8 2.6 29 15
4 stopsol classic* - 16 - 4 float 28 35 4 53 28 26 2.8 2.6 29 15
4 stopsol blue /SuperSilver/ - 16 - 4 float 38 32 14 45 25 36 2.8 2.6 29 15
  * - applies to green color

Advantages:

  • Low sun factor SF, solar protection and low air-conditioning costs during the summer season.

Disadvantages:

  • High coefficient of heat transmission U due to missing energy saving inner glass. This is the reason why we recommend glazing with combined insulating units with the exception of buildings which are to be lived in only seasonally.